EB 575/800

Electronic ballast for use with 575 W and 800 W Metal

Halide Lamps

  • Available for daylight lamps of all well-known manufacturers.
  • In connection with suitable lampheads compensation of cable losses between ballast and lamphead. (CCL – Compensation of Cable Losses)
  • Electronic detection of the used lamp types 575 W and
    800 W.
  • Lamp power constant controlled for steady light quality
    independent of line voltage and of the age of the bulb used.
  • Flicker free operation by use of 75 Hz square wave current.
  • Typical light ripple max. 3% .
  • Additional `low-noise` modes (50 Hz / 60 Hz) to reduce
    the noise that might occur in the lamp head.
  • Optionally equipped with 1000 Hz operation mode for use
    with digital 'high speed' cameras.
  • “Arc Control” to prevent unintended resonance arising inside bulbs of different designs
  • Dimming in range of 50 - 100% of nominal lamp power.
  • With active line filter (PFC) for minimized apparent power and reduced disturbances of Power supply network.
  • Large range for input voltage 90 - 130 V~ /180 - 250 V~.
  • Protection against line overvoltage and overtemperature.
  • Lamp outlet protected against no-load conditions and
    short circuit.
  • Solid aluminum construction witch outside heat sinks.
  • Very silent due to temperature regulated fans.
  • Optionally equipped with digital remote control (DMX512).
Technical Data
Lamp Power 575 W / 800 W
Supply Voltage 90 - 130 V~ / 180 - 250 V~ 50 / 60 Hz 1,N,PE
Line Power

1160 VA (max. in CCL-Mode)

Power Factor cos φ ≈ 0,98
Dimensions
(w •h•d)
202 •141• 335 mm
Weight approx. 6.5 kg